FLEXIBLE COVER FOR CONDUCTORS
Cover for conductors manufactured in orange insulating flexible rubber and in accordance with ASTM D1050 standard requirements. Used as a portable safety device designed to cover exposed energized power lines and to protect electricians from accidental touching and closing circuits during distribution network maintenance.
This cover line has ozone and ultraviolet rays exposure-resistant material (TYPE II), developed for several voltage classes, conductor diameters and lengths.
The cover assembly enjoys the rubber's natural tendency of grabbing and squeezing through compression. The angled end grooves facilitate sliding between covers for installation, but prevent separation during operation. In order to disengage, the operator should only squeeze the rubber on each side.
STYLE A (without nozzle)
Has grooves on its ends for placing and securing nozzles from Style B covers, which aid and ensure the required adherence to prevent sliding during interventions. |
Cat. No. | Type | Nominal Voltage Class | Tension Test Applied | Style | Ø (in) | Length (ft) | Approx. Weight (lb) |
FLX30500-1 | II | 2 (17 kV) | 20 kV | A | 25,4 | 3 | 2.27 |
FLX30500-2 | II | 2 (17 kV) | 20 kV | A | 25,4 | 3.5 | 2.65 |
FLX30500-3 | II | 2 (17 kV) | 20 kV | A | 25,4 | 4.5 | 3.40 |
FLX30500-4 | II | 2 (17 kV) | 20 kV | A | 25,4 | 5 | 3.79 |
FLX30500-5 | II | 2 (17 kV) | 20 kV | A | 25,4 | 6 | 4.54 |
FLX30500-6 | II | 2 (17 kV) | 20 kV | A | 25,4 | 6.5 | 4.92 |
FLX30502-1 | II | 2 (17 kV) | 20 kV | A | 31,8 | 3 | 2.89 |
FLX30502-2 | II | 2 (17 kV) | 20 kV | A | 31,8 | 3.5 | 4.28 |
FLX30504-1 | II | 3 (26,5 kV) | 30 kV | A | 38,1 | 3 | 3.24 |
FLX30504-2 | II | 3 (26,5 kV) | 30 kV | A | 38,1 | 3.5 | 4.87 |
FLX30504-3 | II | 3 (26,5 kV) | 30 kV | A | 38,1 | 5 | 5.42 |
FLX30504-4 | II | 3 (26,5 kV) | 30 kV | A | 38,1 | 6 | 6.50 |
FLX30504-5 | II | 3 (26,5 kV) | 30 kV | A | 38,1 | 6.2 | 6.72 |
STYLE B (with nozzle)
Has grooves on one of its ends and a nozzle on the other for placing and securing, which aid and ensure the required adherence to prevent sliding during interventions. |
Cat. No. | Type | Nominal Voltage Class | Tension Test Applied | Style | Ø (in) | Length (ft) | Approx. Weight (lb) |
FLX30501-1 | II | 2 (17 kV) | 20 kV | B | 1" | 3 | 2.93 |
FLX30501-2 | II | 2 (17 kV) | 20 kV | B | 1" | 3.5 | 3.33 |
FLX30501-3 | II | 2 (17 kV) | 20 kV | B | 1" | 4.5 | 4.79 |
FLX30501-4 | II | 2 (17 kV) | 20 kV | B | 1" | 5 | 4.45 |
FLX30501-5 | II | 2 (17 kV) | 20 kV | B | 1" | 6 | 5.23 |
FLX30501-6 | II | 2 (17 kV) | 20 kV | B | 1" | 6.5 | 5.60 |
FLX30505-1 | II | 3 (26,5 kV) | 30 kV | B | 1,5" | 3 | 4.37 |
FLX30505-2 | II | 3 (26,5 kV) | 30 kV | B | 1,5" | 4.5 | 6.0 |
FLX30505-3 | II | 3 (26,5 kV) | 30 kV | B | 1,5" | 5 | 6.55 |
FLX30505-4 | II | 3 (26,5 kV) | 30 kV | B | 1,5" | 6 | 7.63 |
FLX30505-5 | II | 3 (26,5 kV) | 30 kV | B | 1,5" | 6.5 | 7.85 |